Description
Fully certified
Tested and certified by AARST-NRPP and NRSB for the North American market. Perform your 48-hour testing with ease and confidence.
Highest accuracy
On board ultra-sensitive 30 CPH patented radon detection technology instrumentation for >8X accuracy.
Wi-Fi and Bluetooth
Wi-Fi and Bluetooth are enabled for maximum connectivity and remote monitoring capabilities.
Centralized control and insight
The RadonEye Pro web dashboard makes it easy to monitor, manage devices and generate reports for your clients.
Full-feature smartphone app
Manage inspection (start/finish), generate reports, and share with clients all from the app.
Radon Sensor
Pulsed Ion chamber
Radon Sensitivity
30 CPH (Counts Per Hour) per 1 pCi/L
Radon Accuracy/ Precision
< ±10% at 10 pCi/L after 10 hours
Radon Measurement Rate
Every 10 minutes
Radon Measurement Result
60 minutes moving average
Radon Measurement Range
0.2 ~ 255 pCi/L (7~9,435 Bq/m³)
Connectivity
Wi-Fi, Bluetooth
Radon Alarm
Integrated audio alarm (configurable to set radon level)
Radon Level Visual Indicator
OLED display
Power Supply
12V, 1A, Extend DC adapter
Weight
0.529 lbs (240g)
Operating Temp Range
32°F~104°F (0~40°C)
Does the RadonEye Pro require calibration?
Yes, the RadonEye Pro should have a calibration performed annually. Current Ecosense annual calibration partners are:
For US :
KSU (Kansas State University)
Contact # (785) 532-6026
https://www.ksuradonchamber.org/Calibrations
* Exclusively for the Ecosense RadonEye Pro:
– State-mandated initial calibration certification ($130)
– Annual renewal calibration ($150)
Register/Sign In and Order my Radon Eye Pro Calibration
Bowser-Morner
Contact # (937) 236-8805
https://www.bowser-morner.com/radon-reference-lab
For Canada :
RSIC (Radiation Safety Institute of Canada)
Contact # (416) 650-9090
https://www.radiationsafety.ca/laboratory-services/radon-chamber/
Does the RadonEye Pro come with a battery back-up?
No. If you’d like to use a battery, the Pro requires a 12-volt input. Any standard 5-volt battery pack can also be used, with a 5-volt to 12-volt adapter cable. The required power adapter plug size is 5.5mm x 2.1mm
A 20 Ah battery has a 72-hour life. A 30 Ah battery will increase the battery life to approximately 105 hours.
What does the RadonEye Pro package come with?
The unit ships with a tripod holder, step-up cable, adapter extension cable, battery pouch and carrying bag for inspection (except the tripod, battery itself), and calibration certificate.
I can't read the screen because the text and background color are the same. How can I fix it?
To change the display settings, go to Settings –> Display & Brightness –> Check Light Appearance (Not Dark mode)
Does the Pro generate a report in Becquerels?
Yes, units can be changed using a toggle within the set-up software. However, to generate a report with the changed unit, when setting up the device, you need to connect to Wi-Fi and save the changed unit to the server.
Can the device be attached to a tripod?
Yes. The unit comes with a tripod adapter (not a tripod itself).
Can I turn off the readings on the display?
Yes
What is the latest version of the RadonEye Pro software?
For iOS: iOS 2.0.0
For Android: Android 2.0.1
Does the Pro have any tamper monitoring?
Yes, an accelerometer. It shows the time the device was tempered in the raw data and app.
Does the RadonEye Pro have a reset function?
No, there is no function to reset the device.
It can store up to the following:
– Inspection mode: Max 240h x 10 (2,400 data points)
– Continuous mode: 300days (7,200 data points)
– When the data storage capacity exceeds the capacity, the oldest data is deleted.
How do I access the web dashboard?
Log in to the https://radoneyepro.com homepage.
Do I need to be connected to WiFi to use the RadonEye Pro?
No, the smartphone app connected to the device via Bluetooth is all that you need to set the length of the test, start it, download the test data, and generate a report. If you are connected to WiFi, you will be able to monitor a test while in progress, but not start or stop the test.